GECA GAS TRAIN EQUIPMENT
Gas Filters
Standard specifications
- Operation maximum pressure 6 bar
- Filtration capacity 50µm
- Working Temperature -20°C to +60 °C
- Cartridge Viledon
- Operation maximum pressure 6 bar
- Filtration capacity 50µm
- Working Temperature -20°C to +60 °C
- Cartridge Viledon
- Use non-aggressive gases – Family 1 - 2 - 3 and Air, Special version for Biogas
- Use non-aggressive gases – Family 1 - 2 - 3 and Air, Special version for Biogas
Gas regulators
Standard specifications
- Use Non-aggressive gases of three families - Natural Gas - LPG
- Complete Body Die – Cast Aluminium Gd – AlSi12Cu – EN AB 46100
- Diaphragms NBR 60Sh – DvGW EN 549
- Plastic components Yellow POM / Pa 66 + 25% Gf
- Approval UNI EN 88-1:2011 - PED
- Maximum inlet - 500 mbar, 1 bar, 2 bar, 5 bar, 10 bar, 20 bar
- Setting outlet range 10 - 300 mbar, different setting spring on request
- Filtering <=50um (when supplied)
- Inlet - Outlet Thread gas 1/2", 3/4", 1", 1 ¼”, 1 ½”, 2” - ISO 228
- Connection DN 25 to DN 50 Sliding Aluminium flange PN10
- Connection DN 65 to DN 200 Sliding Aluminium flange PN16
- Test point Inlet / outlet on request, 1/8” NPT
- Working Temperature -20°C to +60° C
Automatic Gas Solenoid Valves
Suitable for various gasses, including Natural gas, Propane and LPG Gas solenoid valve normally closed solenoid that open automatically when the coil is powered and close automatically when there is no tension.
Manual Reset Gas Solenoid valves
Standard specifications
- Power supply: 230VAC - 24 VAC - 24 VDC
- Body: Brass, yellow colour (threaded) / Aluminium (flanged)
- Type: Normally open / Normally close
- Working temperature: -15°C to +70°C
- Closing time: < 1 sec
- Max pressure: 550 mbar / 6 bar
- Protection level: IP65
- Connections: ISO 228/1 thread, flanged UNI 2223
Safety valves
Slam shut-off valve
Size: 1/2”, 3/4”, 1”, 1 ¼”, 1 ½”, 2”, DN65, DN80, DN 100
Standard specifications
- Setting range: 60 - 700 mbar, Standard Spring supplied 200 – 700 mbar
- Closing time <1 second
- Working Temperature - 15 °C / + 70 °C
- Use Non-aggressive gases – Family 1-2-3 and ai
- Approval PED
- Seals NBR
- Internal components Brass
- Body Brass ST-CW617N – EN 12420 – Yellow Painted Die - Cast aluminium Gd - AISi12Cu - EN AB 46100
Manual Gas Ball valves :
Standard specifications
- Female threads. Lever handle in steel.
- Inlet - Outlet Female thread ISO 7/1 Rp parallel
- Connection (equivalent to DIN EN 10226-1 and BS EN 10226-1)
- NPT threads on request
- Working Temperature -20°C to +60° C.
- Approval EN 331
- Maximum pressure 5 bar
- Connection PN16 (flange version)
- Complete Body & flange EN GJS 400-15 / EN GJL250, epoxy coated (flange version)
- Complete Body in nickel-plated brass (threaded version)
Pressure switches
Standard specifications
- Base support Die-casted aluminium
- Set range available from 0.2 to 500 mbar (Maximum pressure 100 mbar to 1 bar)
- Diaphragm NBR
- Housing Brass
- Switch part Polycarbonate
- Electrical rating 230V AC
- Pressure connection 1/4” BSP
- Ambient temperature -15°C to +60 °C
- Enclosure IP54 - IP44 (differential)
- Adjustable tolerance +/- 15%
- Electrical connection male fast – on 6,3 x 0,8 mm
- Air connection Silicone or polyamide, polyurethane hose ø4 x ø7 or ø5 x ø8 mm
- Approval CE according to EN 1854
Pressure Gauge Holder Valve with Pushbutton for Gas
Frequently Asked Questions
GECA Gas Accessories, supplied by Suntec, include gas filters, gas pressure regulators and stabilizers, valves, and complete gas train equipment for safety, regulation, and control.
GECA gas accessories are designed for Natural Gas, LPG, and other non-corrosive gaseous fuels.
GECA gas accessories support a maximum working pressure of 6 bar.
GECA gas accessories are available in sizes from 1/2″ up to 2″, and in DN sizes DN40 through DN200 (DN40, DN50, DN65, DN80, DN100, DN125, DN150, DN200).
Yes. GECA gas filters are designed in accordance with DIN 3386 standards, and are used for filtering Natural Gas, LPG, and non-corrosive gases.
A GECA gas train includes combustion control devices and safety shut-off valves that automatically cut gas supply in emergencies, along with multi-stage regulation systems designed to prevent leaks and pressure irregularities.