GECA GAS TRAIN EQUIPMENT

_
Gas Filters, Gas regulators, valves: all the gas train equipment are available here. Safety, Regulation & control equipment for Natural Gas, LPG & all types of Gaseous fuels.

Gas Filters

Maximum working Pressure : 6 bar
Size : 1/2”, 3/4”, 1”, 1 ¼”, 1 ½”, 2”, DN 40, DN50, DN65, DN80, DN 100, DN 125, DN 150, DN 200
Gas filters are designed in accordance with the provisions of DIN3386 standards. Filters are used for all the types of Natural Gas, LPG or non-corrosive gases. These filters are widely used for protection of control devices, pressure regulators, flow meters and on systems that requiring a high degree of filtration. All the filter covers are filled with connections for test point both at the filter inlet and outlet. 

Standard specifications

_
  • Operation maximum pressure 6 bar
  • Filtration capacity 50µm
  • Working Temperature -20°C to +60 °C
  • Cartridge Viledon
  • Operation maximum pressure 6 bar
  • Filtration capacity 50µm
  • Working Temperature -20°C to +60 °C
  • Cartridge Viledon
  • Use non-aggressive gases – Family 1 - 2 - 3 and Air, Special version for Biogas
  • Use non-aggressive gases – Family 1 - 2 - 3 and Air, Special version for Biogas

Gas regulators

Maximum working Pressure: 500 mbar, 1 bar, 2 bar, 5 bar
Size: 1/2”, 3/4”, 1”, 1 ¼”, 1 ½”, 2”, DN 40, DN50, DN65, DN80, DN 100
Gas pressure regulators and stabilizers: for low and medium pressure levels, here you find the product you need.
Spring-loaded regulators are designed and built according UNI EN 88 class A – group 2 specifications. Same are used for all the types of Natural gas LPG or non-corrosive gases. These regulators are widely used in supply lines for burners and in the piped distribution of methane gas and LPG in both industrial and non-industrial applications. Spring-loaded regulators are self-acting type with balanced obturator and double safety diaphragm. All regulators have internal sensing line and inlet/outlet pressure test point.

Standard specifications

_
  • Use Non-aggressive gases of three families - Natural Gas - LPG
  • Complete Body Die – Cast Aluminium Gd – AlSi12Cu – EN AB 46100
  • Diaphragms NBR 60Sh – DvGW EN 549
  • Plastic components Yellow POM / Pa 66 + 25% Gf
  • Approval UNI EN 88-1:2011 - PED
  • Maximum inlet - 500 mbar, 1 bar, 2 bar, 5 bar, 10 bar, 20 bar
  • Setting outlet range 10 - 300 mbar, different setting spring on request
  • Filtering <=50um (when supplied)
  • Inlet - Outlet Thread gas 1/2", 3/4", 1", 1 ¼”, 1 ½”, 2” - ISO 228
  • Connection DN 25 to DN 50 Sliding Aluminium flange PN10
  • Connection DN 65 to DN 200 Sliding Aluminium flange PN16
  • Test point Inlet / outlet on request, 1/8” NPT
  • Working Temperature -20°C to +60° C

Automatic Gas Solenoid Valves

Maximum working Pressure: 360mbar, 6 bar
Size : 1/2”, 3/4”, 1”, 1 ¼”, 1 ½”, 2”, DN65, DN80, DN 100, DN 150
Automatic gas solenoid valves are used for safety and control of gas for shut-off in gas supply pipes.
Suitable for various gasses, including Natural gas, Propane and LPG Gas solenoid valve normally closed solenoid that open automatically when the coil is powered and close automatically when there is no tension.

Manual Reset Gas Solenoid valves 

Maximum working Pressure: 550mbar, 6 bar
Size: 1/2”, 3/4”, 1”, 1 ¼”, 1 ½”, 2”, DN65, DN80, DN 100, DN 150, DN 200
Gas solenoid valves have been designed to be combined with any gas detection system. Valve shuts off the main outlet when an emergency situation is detected. They have been installed at the gas piping and connected with a gas detector. It closes the gas flow in a danger situation. The electro-valve is normally located after a filter, upstream of the regulation apparatus and preferably outside the measurement zone. It has been installed with the arrow stamped on the body turned towards the user appliance. To reset the solenoid valve, check that the coil is receiving current and pull the reset knob after having unscrewed the protection cap. Screwed it when the operation is finished.

Standard specifications

_
  • Power supply: 230VAC - 24 VAC - 24 VDC
  • Body: Brass, yellow colour (threaded) / Aluminium (flanged)
  • Type: Normally open / Normally close
  • Working temperature: -15°C to +70°C
  • Closing time: < 1 sec
  • Max pressure: 550 mbar / 6 bar
  • Protection level: IP65
  • Connections: ISO 228/1 thread, flanged UNI 2223

Safety valves

Maximum working Pressure: 1 bar
Size: 1/2”, 3/4”, 1”, 1 ¼”, 1 ½”, 2” 
Relief valves are safety devices to avoid dangerous gas over pressures. When the pressure is reached the pre-setting limit, it discharges the required amount of gas outside to bring the pressure back to safe values. The operating principle is the balance between thrust pressure on the inner membrane and the opposing force of the spring, whose characteristic defines the pressure to be vented out.

Slam shut-off valve

The Slam shut-off valves close the supply of gas when a downstream pressure exceed a pre-determined limit. These are safety devices and they can be reopened only by manual operation.
Maximum working Pressure: 6 bar
Size: 1/2”, 3/4”, 1”, 1 ¼”, 1 ½”, 2”, DN65, DN80, DN 100

Standard specifications

_
  • Setting range: 60 - 700 mbar, Standard Spring supplied 200 – 700 mbar
  • Closing time <1 second
  • Working Temperature - 15 °C / + 70 °C
  • Use Non-aggressive gases – Family 1-2-3 and ai
  • Approval PED
  • Seals NBR
  • Internal components Brass
  • Body Brass ST-CW617N – EN 12420 – Yellow Painted Die - Cast aluminium Gd - AISi12Cu - EN AB 46100

Manual Gas Ball valves :

Connection ½, ¾”, 1”, 1 ¼”, 1 ½”, 2”, DN 65, DN 80, DN 100, DN 125, DN 150, DN 200

Standard specifications

_
  • Female threads. Lever handle in steel.
  • Inlet - Outlet Female thread ISO 7/1 Rp parallel
  • Connection (equivalent to DIN EN 10226-1 and BS EN 10226-1)
  • NPT threads on request
  • Working Temperature -20°C to +60° C.
  • Approval EN 331
  • Maximum pressure 5 bar
  • Connection PN16 (flange version)
  • Complete Body & flange EN GJS 400-15 / EN GJL250, epoxy coated (flange version)
  • Complete Body in nickel-plated brass (threaded version)

Pressure switches

Pressure switches are designed for switching a circuit on, off or over if the pressure actual value changes in relation to the setpoint. Available in different configuration positive, differential and positive/differential pressure.

Standard specifications

_
  • Base support Die-casted aluminium
  • Set range available from 0.2 to 500 mbar (Maximum pressure 100 mbar to 1 bar)
  • Diaphragm NBR
  • Housing Brass
  • Switch part Polycarbonate
  • Electrical rating 230V AC
  • Pressure connection 1/4” BSP
  • Ambient temperature -15°C to +60 °C
  • Enclosure IP54 - IP44 (differential)
  • Adjustable tolerance +/- 15%
  • Electrical connection male fast – on 6,3 x 0,8 mm
  • Air connection Silicone or polyamide, polyurethane hose ø4 x ø7 or ø5 x ø8 mm
  • Approval CE according to EN 1854

Pressure Gauge Holder Valve with Pushbutton for Gas

They protect the capsule pressure gauges, keeping them isolated from the system. To read the pressure gauge, press the valve button.
Size available: ¼”, 3/8”, ½”